2.1.
Roof
I.
The inspector shall inspect from ground
level or eaves:
A. The roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights,
chimney and other roof penetrations.
E. The general structure of the roof from
the readily accessible panels, doors or
stairs.
II.
The inspector is not required to:
A. Walk on any roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter
drainage pipes.
D. Remove snow, ice, debris or other
conditions that prohibit the observation
of the roof surfaces.
E. Inspect antennae, lightning arresters,
or similar attachments.
2.2.
Exterior
I.
The inspector shall inspect:
A. The siding,
flashing and trim.
B. All exterior doors, decks, stoops,
steps, stairs, porches, railings, eaves,
soffits and fascias.
C. And report as
in need of repair any spacings between
intermediate balusters, spindles, or
rails for steps, stairways, balconies,
and railings that permit the passage of
an object greater than four inches in
diameter.
D. A represntative
number of windows.
E. The vegetation, surface drainage and
retaining walls when these are likely to
adversely affect the structure.
F. And describe the exterior wall
covering.
II.
The inspector is not required to:
A. Inspect or operate screens, storm
windows, shutters, awnings, fences,
outbuildings, or exterior accent lighting.
B. Inspect items, including window and
door flashings, which are not visible or
readily accessible from the ground.
C. Inspect geological,
geotechnical, hydrological and/or soil
conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and
docks.
F. Inspect erosion control and earth
stabilization measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal
window seals or damaged glass.
2.3.
Basement, Foundation & Crawlspace
I.
The inspector shall inspect:
A. The basement.
B. The foundation
C. The crawlspace.
D. The visible structural components.
E. Any present conditions or
clear indications of active water
penetration observed by the inspector.
F. And report any
general indications of foundation
movement that are observed by the
inspector, such as but not limited to
sheetrock cracks, brick cracks,
out-of-square door frames or floor
slopes.
II.
The inspector is not required to:
A. Enter any crawlspaces that are not
readily accessible or where entry could
cause damage or pose a hazard to the
inspector.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible
floats.
D. Identify size, spacing, span, location
or determine adequacy of foundation
bolting, bracing, joists, joist spans or
support systems.
E. Provide any engineering or
architectural service.
F. Report on the adequacy of any
structural system or component.
2.4. Heating
I.
The inspector shall inspect:
A. The heating system and describe the
energy source and heating method using
normal operating controls.
B. And report as in need of repair
electric furnaces which do not operate.
C. And report if inspector deemed the
furnace inaccessible.
II.
The inspector is not required to:
A. Inspect or
evaluate interiors of flues or chimneys,
fire chambers, heat
exchangers, humidifiers, dehumidifiers,
electronic air filters, solar heating
systems, solar heating systems or fuel
tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity,
temperature, flow, balance,
distribution, size, capacity, BTU, or
supply adequacy of the heating system.
D. Light or ignite pilot flames.
E. Activate heating, heat pump systems,
or other heating systems when ambient
temperatures or when other circumstances
are not conducive to safe operation or
may damage the equipment.
F. Override electronic thermostats.
G. Evaluate fuel quality.
H. Verify
theromstat calibration, heat
anticipation or automatic setbacks,
timers, programs or clocks.
2.5.
Cooling
I.
The inspector shall inspect:
A. The central cooling equipment using
normal operating controls.
II.
The inspector is not required to:
A. Determine the uniformity, temperature,
flow, balance, distribution, size,
capacity, BTU, or supply adequacy of the
cooling system.
B. Inspect window units, through-wall
units, or electronic air filters.
C. Operate equipment or systems if
exterior temperature is below 60 degrees
Fahrenheit or when other circumstances are
not conducive to safe operation or may
damage the equipment.
D. Inspect or determine thermostat
calibration, heat anticipation or
automatic setbacks or clocks.
E. Examine electrical current, coolant
fluids or gasses, or coolant leakage.
2.6.
Plumbing
I.
The inspector shall:
A. Verify the
presence of and identify the location of
the main water shutoff valve.
B. Inspect the water heating equipment,
including combustion air, venting,
connections, energy sources, seismic
bracing, and verify the presence or
absence of temperature-pressure relief
valves and/or Watts 210 valves.
C. Flush toilets.
D. Run water in sinks, tubs, and
showers.
E. Inspect the interior water supply
including all fixtures and faucets.
F. Inspect the drain, waste and vent
systems, including all fixtures.
G. Describe any visible fuel storage
systems.
H. Inspect the drainage sump pumps
testing sumps with accessible floats.
I. Inspect and describe the water
supply, drain, waste and main fuel
shut-off valves, as well as the location
of the water main and main fuel shut-off
valves.
J. Inspect and determine if the water
supply is public or private.
K. Inspect and report as in need of
repair deficiencies in the water supply
by viewing the functional flow in two
fixtures operated simultaneously.
L. Inspect and report as in need of
repair deficiencies in installation and
identification of hot and cold faucets.
M. Inspect and report as in need of
repair mechanical drain-stops that are
missing or do not operate if installed
in sinks, lavatories and tubs.
N. Inspect and report as in need of
repair commodes that have cracks in the
ceramic material, are improperly mounted
on the floor, leak, or have tank
components which do not operate.
II.
The inspector is not required to:
A. Light or ignite
pilot flames.
B. Determine the size, temperature, age,
life expectancy or adequacy of the water
heater.
C. Inspect interiors of flues or
chimneys, water softening or filtering
systems, well pumps or tanks, safety or
shut-of valves, floor drains, lawn
sprinkler systems or fire sprinkler
systems.
D. Determine the exact flow rate,
volume, pressure, temperature, or
adequacy of the water supply.
E. Determine the water quality or
potability or the reliability of the
water supply or source.
F. Open sealed plumbing access panels.
G. Inspect clothes washing machines or
their connections.
H. Operate any main, branch or fixture
valve.
I. Test shower
pans, tub and shower surrounds or
enclosures for leakage.
J. Evaluate the compliance with local or
state conservation or energy standards,
or the proper design or sizing of any
water, waste or venting components,
fixtures or piping.
K. Determine the effectiveness of
anti-siphon, back-flow prevention or
drain-stop devices.
L. Determine whether there are
sufficient clean-outs for effective
cleaning of drains.
M. Evaluate gas, liquid propane or oil
storage tanks.
N. Inspect any private sewage waste
disposal system or component of.
O. Inspect water treatment systems or
water filters.
P. Inspect water storage tanks, pressure
pumps or bladder tanks.
Q. Evaluate time
to obtain hot water at fixtures, or
perform testing of any kind to water
heater elements.
R. Evaluate or
determine the adequacy of combustion
air.
S. Test,
operate, open or close safety
controls, manual stop valves and/or
temperature or pressure releif valves.
T. Examine
ancillary systems or components, such
as, but not limited to, those relating
to solar water heating, hot water
circulation.
2.7.
Electrical
I.
The inspector shall inspect:
A. The service
line.
B. The meter box.
C. The main disconnect.
D. And determine the rating of the
service amperage.
E. Panels, breakers and fuses.
F. The service grounding and bonding.
H. A representative sampling of
switches, receptacles, light fixtures,
AFCI receptacles
I. And test all
GFCI receptacles and GFCI circuit
breakers observed and deemed to be
GFCI's during the inspection.
I. And report the
presence of solid conductor aluminum
branch circuit wiring if readily
visible.
J. And report on any
GFCI-tested receptacles in which power
is not present, polarity is incorrect,
the receptacle is not grounded, is not
secured to the wall, the cover is not in
place, the ground fault circuit
interrupter devices are not properly
installed or do not operate properly, or
evidence of arcing or excessive heat is
present.
K. The service entrance conductors and
the condition of their sheathing.
L. The ground fault circuit interrupters
observed and deemed to be GFCI's during
the inspection with a GFCI tester.
M. And describe the amperage rating of
the service.
N. And report the absence of smoke
detectors.
O. Service entrance cables and report as
in need of repair deficiencies in the
integrity of the insulation, drip loop,
or separation of conductors at
weatherheads and clearances.
II.
The inspector is not required to:
A. Insert any tool, probe or device into
the main panel, sub-panels, downstream
panesl, or electrical fixtures.
B. Operate electrical systems that are
shut down.
C. Remove panel covers or dead front
covers if not readily accessible.
D. Operate over current protection
devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or
voltage of the main service if not visibly
labeled.
G. Inspect the alarm system and
components.
H. Inspect the ancillary wiring or remote
control devices.
I. Activate any electrical systems or
branch circuits which are not energized.
J. Operate overload devices.
K. Inspect low voltage systems, electrical
de-icing tapes, swimming pool wiring or
any time-controlled devices.
L. Verify the continuity of the connected
service ground.
M. Inspect private or emergency electrical
supply sources, including but not limited
to generators, windmills, photovoltaic
solar collectors, or battery or electrical
storage facility.
N. Inspect spark or lightning arrestors.
O. Conduct voltage drop calculations.
P. Determine the accuracy of breaker
labeling.
2.8.
Fireplace
I.
The inspector shall inspect:
A. The fireplace, and open and close the
damper door if readily accessible and
operable.
B. Hearth extensions and other permanently
installed components.
C. And report as in need of repair
deficiencies in the lintel, hearth and
material surrounding the fireplace,
including clearance from combustible
materials
II.
The inspector is not required to:
A. Inspect the
flue or vent system.
B. Inspect the interior of chimneys or
flues, fire doors or screens, seals or
gaskets, or mantels.
C. Determine the need for a chimney
sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of such
installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion and/or make-up
air devices.
I. Inspect heat distribution assists
whether gravity controlled or fan
assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or
firebox contents.
M. Determine adequacy of draft, perform
a smoke test or dismantle or remove any
component.
N. Perform an NFPA
inspection.
2.9.
Attic, Ventilation & Insulation
I.
The inspector shall inspect:
A. The insulation in unfinished spaces.
B. The ventilation of attic spaces.
C. Mechanical ventilation systems.
D. And report on the general absence or
lack of insulation.
II.
The inspector is not required to:
A. Enter the attic
or unfinished spaces that are not
readily accessible or where entry could
cause damage or pose a safety hazard to
the inspector in his or her opinion.
B. To move, touch, or
disturb insulation.
C. To move, touch or disturb vapor
retarders.
D. Break or otherwise damage the surface
finish or weather seal on or around
access panels and covers.
E. Identify the composition of or the
exact R-value of insulation material.
F. Activate thermostatically operated
fans.
G. Determine the types of materials used
in insulation/wrapping of pipes, ducts,
jackets, boilers, and wiring.
H. Determin
adequacy of ventilation.
2.10.
Doors, Windows & Interior
I.
The inspector shall:
A. Open and close a representative number
of doors and windows.
B. Inspect the walls, ceilings, steps,
stairways, and railings.
C. Inspect garage doors and garage door
openers by operating first by remote (if
available) and then by the installed
automatic door control.
D. And report as in need of repair any
installed electronic sensors that are not
operable or not installed at proper
heights above the garage door.
E. And report as in need of repair any
door locks or side ropes that have not
been removed or disabled when garage door
opener is in use.
F. And report as in need of repair any
windows that are obviously fogged or
display other evidence of broken seals.
II.
The inspector is not required to:
A. Inspect paint, wallpaper, window
treatments or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing.
D. Inspect security systems or components.
E. Evaluate the fastening of countertops,
cabinets, sink tops and fixtures, or
firewall compromises.
F. Move furniture, stored items, or any
coverings like carpets or rugs in order to
inspect the concealed floor structure.
G. Move drop ceiling tiles.
H. Inspect or move any household
appliances..
I. Inspect or operate equipment housed in
the garage except as otherwise noted.
J. Verify or certify safe operation of any
auto reverse or related safety function of
a garage door.
K. Operate or evaluate security bar
release and opening mechanisms, whether
interior or exterior, including compliance
with local, state, or federal standards.
L. Operate any system, appliance or
component that requires the use of special
keys, codes, combinations, or devices.
M. Operate or evaluate self-cleaning oven
cycles, tilt guards/latches or signal
lights.
N. Inspect microwave ovens or test leakage
from microwave ovens.
O. Operate or examine any sauna,
steam-jenny, kiln, toaster, ice-maker,
coffee-maker, can-opener, bread-warmer,
blender, instant hot water dispenser, or
other small, ancillary devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently
installed.
T. Examine or operate any above-ground,
movable, freestanding, or otherwise
non-permanently installed pool/spa,
recreational equipment or self-contained
equipment.
U. Come into contact with any pool or spa
water in order to determine the system
structure or components.
V. Determine the adequacy of spa jet water
force or bubble effect.
W. Determine the structural integrity or
leakage of a pool or spa.
3. Limitations, Exceptions & Exclusions
3.1.
Limitations:
I.
An inspection is not technically exhaustive.
II. An inspection will not identify
concealed or latent defects.
III. An inspection will not deal with
aesthetic concerns or what could be deemed
matters of taste, cosmetic, etc.
IV. An inspection will not determine the
suitability of the property for any use.
V. An inspection does not determine the
market value of the property or its
marketability.
VI. An inspection does not determine the
advisability or inadvisability of the
purchase of the inspected property.
VII. An inspection does not determine the
life expectancy of the property or any
components or systems therein.
VIII. An inspection does not include items
not permanently installed.
IX. These Standards of Practice apply only
to homes with four or fewer dwelling units.
3.2. Exclusions:
I.
The inspectors are not required to
determine:
A. Property boundary lines or
encroachments.
B. The condition of any component or
system that is not readily accessible.
C. The service life expectancy of any
component or system.
D. The size, capacity, BTU, performance,
or efficiency of any component or system.
E. The cause or reason of any condition.
F. The cause for the need of repair or
replacement of any system or component.
G. Future conditions.
H. The compliance with codes or
regulations.
I. The presence of evidence of rodents,
animals or insects.
J. The presence of mold, mildew or fungus.
K. The presence of air-borne hazards.
L. The presence of birds.
M. The presence of other flora or fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental hazards.
Q. The existence of electro-magnetic
fields.
R. The presence of hazardous materials
including, but not limited to, the
presence of lead in paint.
S. Any hazardous waste conditions.
T. Any manufacturer recalls or conformance
with manufacturer installation or any
information included in the consumer
protection bulletin.
U. Operating costs of systems.
V. Replacement or repair cost estimates.
W. The acoustical properties of any
systems.
X. Estimates of how much it will cost to
run any given system.
II.
The inspectors are not required to operate:
A. Any system that is shut down.
B. Any system that does not function
properly.
C. Or evaluate low voltage electrical
systems such as, but not limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on with
the use of normal operating controls.
E. Any shut off valves or manual stop
valves.
F. Any electrical disconnect or over
current protection devices.
G. Any alarm systems.
H. Moisture meters, gas detectors or
similar equipment.
III. The inspectors are not required to:
A. Move any personal items or other
obstructions, such as, but not limited to:
1. Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
8. Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
B. Dismantle,
open, or uncover any system or
component.
C. Enter or access any area which may,
in the opinion of the inspector, to be
unsafe or risk personal safety.
D. Enter crawlspaces or other areas that
are unsafe or not readily accessible.
E. Inspect underground items such as,
but not limited to, underground storage
tanks or other indications of their
presence, whether abandoned or actively
used.
F. Do anything which, in the inspector's
opinion, is likely to be unsafe or
dangerous to the inspector or others or
damage property, such as, but not
limited to, walking on roof surfaces,
climbing ladders, entering attic spaces
or negotiating with dogs.
G. Inspect decorative items.
H. Inspect common elements or areas in
multi-unit housing.
I. Inspect intercoms, speaker systems,
radio-controlled, security devices or
lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering
services.
L. Offer or perform any trade or
professional service other than home
inspection.
M. Research the history of the property,
report on its potential for alteration,
modification, extendibility, or its
suitability for a specific or proposed
use for occupancy.
N. Determine the age of construction or
installation of any system structure, or
component of a building, or
differentiate between original
construction or subsequent additions,
improvements, renovations or
replacements thereto.
O. Determine the insurability of a
property.
P. Perform or
offer Phase 1 environmental audits.
Q. Inspect on any
system or component which is not
included in these standards.
4. Glossary of Terms
4.1.
Accessible: Can be approached or entered by
the inspector safely, without difficulty, fear
or danger.
4.2.
Activate: To turn on, supply power, or enable
systems, equipment, or devices to become
active by normal operating controls. Examples
include turning on the gas or water supply
valves to the fixtures and appliances and
activating electrical breakers or fuses.
4.3.
Adversely Affect: Constitute, or potentially
constitute, a negative or destructive impact.
4.4.
Alarm System: Warning devices, installed or
free-standing, including but not limited to:
Carbon monoxide detectors, flue gas and other spillage
detectors, security equipment, ejector pumps
and smoke alarms.
4.5.
Appliance: A household device operated by use
of electricity or gas. Not included in this
definition are components covered under
central heating, central cooling or plumbing.
4.6.
Architectural Service: Any practice involving
the art and science of building design for
construction of any structure or grouping of
structures and the use of space within and
surrounding the structures or the design,
design development, preparation of
construction contract documents, and
administration of the construction contract.
4.7.
Component: A permanently installed or attached
fixture, element or part of a system.
4.8.
Condition: The visible and conspicuous state
of being of an object.
4.9.
Crawlspace: The area within the confines of
the foundation and between the ground and the
underside of the lowest floor structural
component.
4.10.
Decorative: Ornamental; not required for the
operation of essential systems and components
of a home.
4.11.
Describe: Report in writing a system or
component by its type, or other observed
characteristics, to distinguish it from other
components used for the same purpose.
4.12.
Determine: To arrive at an opinion or
conclusion pursuant to examination.
4.13.
Dismantle: To open, take apart or remove any
component, device or piece that would not
typically be opened, taken apart or removed by
an ordinary occupant.
4.14.
Engineering Service: Any professional service
or creative work requiring engineering
education, training, and experience and the
application of special knowledge of the
mathematical, physical and engineering
sciences to such professional service or
creative work as consultation, investigation,
evaluation, planning, design and supervision
of construction for the purpose of assuring
compliance with the specifications and design,
in conjunction with structures, buildings,
machines, equipment, works or processes.
4.15.
Enter: To go into an area to observe visible
components.
4.16.
Evaluate: To assess the systems, structures or
components of a dwelling.
4.17.
Examine: To visually look. See Inspect.
4.18.
Foundation: The base upon which the structure
or wall rests; usually masonry, concrete, or
stone, and generally partially underground.
4.19.
Function: The action for which an item,
component, or system is specially fitted or
used or for which an item, component or system
exists; to be in action or perform a task.
4.20.
Functional: Performing, or able to perform, a
function.
4.21.
Home Inspection: The process by which an
inspector visually examines the readily
accessible systems and components of a home
and operates those systems and components
utilizing these Standards of Practice as a
guideline.
4.22.
Household Appliances: Kitchen and laundry
appliances, room air conditioners, and similar
appliances.
4.23. Inspect: To visually look at readily
accessible systems and components safely,
using normal operating controls and
accessing readily accessible panels and
areas in accordance with these Standards of
Practice.
4.24. Inspected Property: The readily
accessible areas of the buildings, site,
items, components, and systems included in
the inspection.
4.25.
Inspector: One who performs a real estate
inspection.
4.26.
Installed: Attached or connected such that the
installed item requires tool for removal.
4.27.
Material Defect: Refer to section 1.2.
4.28.
Normal Operating Controls: Devices such as
thermostats that would be operated by ordinary
occupants which require no specialized skill
or knowledge.
4.29.
Observe: To see through visually directed
attention.
4.30.
Operate: To cause systems to function or turn
on with normal operating controls.
4.31.
Readily Accessible: An item or component is
readily accessible if, in the judgment of the
inspector, it is capable of being safely
observed without movement of obstacles,
detachment or disengagement of connecting or
securing devices, or other unsafe or difficult
procedures to gain access.
4.32.
Recreational Facilities: Spas, saunas, steam
baths, swimming pools, tennis courts,
playground equipment, and other exercise,
entertainment or athletic facilities.
4.33.
Report: A written communication (possibly
including digital images) of any material
defects seen during the inspection.
4.34.
Representative Number: A sufficient number to
serve as a typical or characteristic example
of the item(s) inspected.
4.35.
Safety Glazing: Tempered glass, laminated
glass, or rigid plastic.
4.36.
Shut Down: Turned off, unplugged, inactive,
not in service, not operational, etc.
4.37.
Structural Component: A component which
supports non-variable forces or weights (dead
loads) and variable forces or weights (live
loads).
4.38.
System: An assembly of various components to
function as a whole.
4.39.
Technically Exhaustive: A comprehensive and
detailed examination beyond the scope of a
real estate home inspection which would
involve or include, but would not be limited
to: dismantling, specialized knowledge or
training, special equipment, measurements,
calculations, testing, research, analysis or
other means.
4.40.
Unsafe: A condition in a readily accessible,
installed system or component which is judged
to be a significant risk of personal injury
during normal, day-to-day use. The risk may be
due to damage, deterioration, improper
installation or a change in accepted
residential construction standards.
4.41.
Verify: To confirm or substantiate.